{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-86151",
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "state": "PUBLISHED",
        "assignerShortName": "VulDB",
        "dateReserved": "2026-09-05T07:40:27.346Z",
        "datePublished": "2026-09-05T23:45:09.354Z",
        "dateUpdated": "2026-09-11T20:37:13.261Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
                "shortName": "VulDB",
                "dateUpdated": "2026-09-05T23:45:09.354Z"
            },
            "title": "Tenda CP3 Network Configuration Management system.c sub_2F77E8 os command injection",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "type": "CWE",
                            "cweId": "CWE-78",
                            "lang": "en",
                            "description": "OS Command Injection"
                        }
                    ]
                },
                {
                    "descriptions": [
                        {
                            "type": "CWE",
                            "cweId": "CWE-77",
                            "lang": "en",
                            "description": "Command Injection"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "Tenda",
                    "product": "CP3",
                    "versions": [
                        {
                            "version": "27.5.57.101",
                            "status": "affected"
                        }
                    ],
                    "cpes": [
                        "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
                    ],
                    "modules": [
                        "Network Configuration Management"
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A vulnerability was detected in Tenda CP3 27.5.57.101. The affected element is the function sub_2F77E8 of the file Apis/system.c of the component Network Configuration Management. Performing a manipulation results in os command injection. The attack may be initiated remotely."
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "version": "4.0",
                        "baseScore": 9.4,
                        "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
                        "baseSeverity": "CRITICAL"
                    }
                },
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "baseScore": 9.1,
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                        "baseSeverity": "CRITICAL"
                    }
                },
                {
                    "cvssV3_0": {
                        "version": "3.0",
                        "baseScore": 9.1,
                        "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                        "baseSeverity": "CRITICAL"
                    }
                },
                {
                    "cvssV2_0": {
                        "version": "2.0",
                        "baseScore": 8.3,
                        "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:ND/RL:ND/RC:UR"
                    }
                }
            ],
            "timeline": [
                {
                    "time": "2026-09-05T00:00:00.000Z",
                    "lang": "en",
                    "value": "Advisory disclosed"
                },
                {
                    "time": "2026-09-05T02:00:00.000Z",
                    "lang": "en",
                    "value": "VulDB entry created"
                },
                {
                    "time": "2026-09-05T09:45:52.000Z",
                    "lang": "en",
                    "value": "VulDB entry last update"
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "FengZi (VulDB User)",
                    "type": "reporter"
                },
                {
                    "lang": "en",
                    "value": "VulDB Vulnerability Moderation Team",
                    "type": "coordinator"
                }
            ],
            "references": [
                {
                    "url": "https://vuldb.com/vuln/399274",
                    "name": "VDB-399274 | Tenda CP3 Network Configuration Management system.c sub_2F77E8 os command injection",
                    "tags": [
                        "vdb-entry",
                        "technical-description"
                    ]
                },
                {
                    "url": "https://vuldb.com/vuln/399274/cti",
                    "name": "VDB-399274 | CTI Indicators (IOB, IOC, TTP, IOA)",
                    "tags": [
                        "signature",
                        "permissions-required"
                    ]
                },
                {
                    "url": "https://vuldb.com/cve/CVE-2026-86151",
                    "name": "CVE-2026-86151 | CVE Analysis and Report",
                    "tags": [
                        "third-party-advisory"
                    ]
                },
                {
                    "url": "https://vuldb.com/submit/895352",
                    "name": "Submit #895352 | Tenda CP3 V3.2 V27.5.57.101 OS Command Injection",
                    "tags": [
                        "third-party-advisory"
                    ]
                },
                {
                    "url": "https://www.tenda.com.cn/",
                    "tags": [
                        "product"
                    ]
                }
            ],
            "x_generator": [
                "VulDB PVTS v202609"
            ]
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2026-09-11T20:15:50.551027Z",
                                "id": "CVE-2026-86151",
                                "options": [
                                    {
                                        "Exploitation": "poc"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2026-09-11T20:37:13.261Z"
                }
            }
        ]
    }
}