    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-72510",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2026-08-10T17:31:09.979Z",
        "datePublished": "2026-09-29T21:28:26.762Z",
        "dateUpdated": "2026-09-29T21:28:26.762Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2026-09-29T21:28:26.762Z"
            },
            "title": "Toptech TMS7 and TopHAT SQL Injection",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-89",
                            "description": "CWE-89",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "Toptech Systems",
                    "product": "TMS7",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "7.6.3"
                        },
                        {
                            "status": "unaffected",
                            "version": "7.8"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Toptech Systems",
                    "product": "TopHAT",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "7.6.3"
                        },
                        {
                            "status": "unaffected",
                            "version": "7.8"
                        }
                    ],
                    "defaultStatus": "unaffected"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "The \"supplier_no\" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "The \"supplier_no\" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection."
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://www.toptech.com/blog/tms7-version-7-8-strengthens-security"
                },
                {
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-02"
                },
                {
                    "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-02.json"
                }
            ],
            "metrics": [
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV3_1": {
                        "version": "3.1",
                        "attackVector": "NETWORK",
                        "attackComplexity": "LOW",
                        "privilegesRequired": "HIGH",
                        "userInteraction": "NONE",
                        "scope": "CHANGED",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "LOW",
                        "availabilityImpact": "HIGH",
                        "baseSeverity": "CRITICAL",
                        "baseScore": 9,
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H"
                    }
                },
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV4_0": {
                        "attackVector": "NETWORK",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "privilegesRequired": "HIGH",
                        "userInteraction": "NONE",
                        "vulnConfidentialityImpact": "HIGH",
                        "subConfidentialityImpact": "HIGH",
                        "vulnIntegrityImpact": "LOW",
                        "subIntegrityImpact": "LOW",
                        "vulnAvailabilityImpact": "HIGH",
                        "subAvailabilityImpact": "HIGH",
                        "exploitMaturity": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "valueDensity": "NOT_DEFINED",
                        "vulnerabilityResponseEffort": "NOT_DEFINED",
                        "providerUrgency": "NOT_DEFINED",
                        "version": "4.0",
                        "baseSeverity": "HIGH",
                        "baseScore": 8.5,
                        "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H"
                    }
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.\n https://www.toptech.com/blog/tms7-version-7-8-strengthens-security",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "Toptech Systems sent a security advisory to their customers on July 20, 2026. The issue has been addressed in release 7.8. Users can get the latest release and more information on this issue at the Toptech Systems security blog.<br><a href=\"https://www.toptech.com/blog/tms7-version-7-8-strengthens-security\">https://www.toptech.com/blog/tms7-version-7-8-strengthens-security</a>"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "Sachin Shetty and Roy Duisters of Shell CyberDefence reported this vulnerability to Toptech and CISA.",
                    "type": "finder"
                }
            ],
            "source": {
                "advisory": "ICSA-26-272-02",
                "discovery": "EXTERNAL"
            },
            "x_generator": {
                "engine": "Vulnogram 1.0.5"
            }
        }
    }
}