synced 13 MIN AGO
01 Record

CVE-2026-71919

DrayTek VigorSwitch Multiple Models OS Command Injection via sysreboot

HighPUBLISHEDCNA: VulnCheck
CNA base score8.6 CVSS v4.0CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

02 Description

DrayTek VigorSwitch Multiple Models OS Command Injection via sysreboot

03 Exploitation and scoring

Exploitation
Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
SSVC decision
  • ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
  • AutomatablenoAt least one step from reconnaissance to exploitation cannot be reliably automated.
  • Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
CISA publishes the decision points, not a final SSVC decision. The decision also depends on mission and well-being impact, which is a property of your deployment rather than of the vulnerability.
EPSS probability
2.26% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 82.7% of scored records. A rank, not a probability.
NVD base score
8.6 (CVSS v4.0), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD analysis status
Deferred. NVD last modified this record on 2026-10-13.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2026-08-24 17:07Z2 MO AGO
Last updated
2026-08-24 19:54Z2 MO AGO
Reserved
2026-08-08
Assigning CNA
VulnCheck
Record state
PUBLISHED
Severity
High (CVSS 8.6)
CNA CVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Weaknesses
  • CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')Base
Data version
5.2
Document digest
7d20d74688f07535b3d8b09c562bfcef3f4ec373db4ceaaf72210371f41cc49e

05 Affected products

VendorProductVersionsPlatforms
DrayTek CorporationVigorSwitch G2540xs0 to < 3.9.10—
DrayTek CorporationVigorSwitch P2540xs0 to < 3.9.10—
DrayTek CorporationVigorSwitch FX21200 to < 3.9.10—
DrayTek CorporationVigorSwitch G2282x0 to < 2.10.6—
DrayTek CorporationVigorSwitch P2282x0 to < 2.10.6—
DrayTek CorporationVigorSwitch Q2300x0 to < 2.10.7—
DrayTek CorporationVigorSwitch PQ2300xb0 to < 2.10.7—
DrayTek CorporationVigorSwitch G2542x0 to < 3.10.6—
DrayTek CorporationVigorSwitch P2542x0 to < 3.10.6—
DrayTek CorporationVigorSwitch P2542xh0 to < 3.10.6—
DrayTek CorporationVigorSwitch PX20600 to < 2.9.10—
DrayTek CorporationVigorSwitch G12800 to < 2.9.10—
DrayTek CorporationVigorSwitch P12800 to < 2.9.10—
DrayTek CorporationVigorSwitch P1281x0 to < 2.9.10—
DrayTek CorporationVigorSwitch G12820 to < 2.9.10—
DrayTek CorporationVigorSwitch P12820 to < 2.9.10—
DrayTek CorporationVigorSwitch G21210 to < 2.9.10—
DrayTek CorporationVigorSwitch P21210 to < 2.9.10—
DrayTek CorporationVigorSwitch PQ2121x0 to < 2.9.10—
DrayTek CorporationVigorSwitch Q2121x0 to < 2.9.10—
DrayTek CorporationVigorSwitch G2280x0 to < 2.9.10—
DrayTek CorporationVigorSwitch P2280x0 to < 2.9.10—
DrayTek CorporationVigorSwitch Q2200x0 to < 2.9.10—
DrayTek CorporationVigorSwitch PQ2200xb0 to < 2.9.10—
DrayTek CorporationVigorSwitch G21000 to < 2.9.10—
DrayTek CorporationVigorSwitch P21000 to < 2.9.10—
DrayTek CorporationVigorSwitch G2540x0 to < 2.9.10—
DrayTek CorporationVigorSwitch P2540x0 to < 2.9.10—

06 References