    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-68967",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2026-08-10T16:03:40.497Z",
        "datePublished": "2026-08-27T20:50:22.011Z",
        "dateUpdated": "2026-08-27T20:50:22.011Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2026-08-27T20:50:22.011Z"
            },
            "title": "Out-of-bounds Write in Bendix EC80 Brake ECU",
            "datePublic": "2026-08-25T14:28:00.000Z",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-787",
                            "description": "CWE-787",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP+ J1708",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z228999"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z300822"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP+ 6S/6M",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z228999"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z300822"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP+ PLC",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z228999"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z300822"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP+ 2nd CAN",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z228999"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z300822"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP+ Integrated TPMS",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z228999"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z300822"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP 6S/6M",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z266494"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z302578"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP PLC",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z266494"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z302578"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP 2nd CAN",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z266494"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z302578"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP CAN Gateway",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z266494"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z302578"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP 4S/4M",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z286098"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z302579"
                        }
                    ],
                    "defaultStatus": "unaffected"
                },
                {
                    "vendor": "Bendix",
                    "product": "EC80ESP PLC",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Z286098"
                        },
                        {
                            "status": "unaffected",
                            "version": "Z302579"
                        }
                    ],
                    "defaultStatus": "unaffected"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "Bendix EC80 Brake ECU is vulnerable to an out-of-bounds write, which could allow an attacker \nto deliver a payload that could establish an arbitrary write primitive, \nwhich could crash the ECU.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "Bendix EC80 Brake ECU&nbsp;is vulnerable to an out-of-bounds write, which could allow an attacker \nto deliver a payload that could establish an arbitrary write primitive, \nwhich could crash the ECU."
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05"
                },
                {
                    "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json"
                }
            ],
            "metrics": [
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV3_1": {
                        "version": "3.1",
                        "attackVector": "ADJACENT_NETWORK",
                        "attackComplexity": "LOW",
                        "privilegesRequired": "NONE",
                        "userInteraction": "NONE",
                        "scope": "UNCHANGED",
                        "confidentialityImpact": "NONE",
                        "integrityImpact": "HIGH",
                        "availabilityImpact": "NONE",
                        "baseSeverity": "MEDIUM",
                        "baseScore": 6.5,
                        "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
                    }
                },
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV4_0": {
                        "attackVector": "ADJACENT",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "privilegesRequired": "NONE",
                        "userInteraction": "NONE",
                        "vulnConfidentialityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "vulnIntegrityImpact": "HIGH",
                        "subIntegrityImpact": "NONE",
                        "vulnAvailabilityImpact": "NONE",
                        "subAvailabilityImpact": "NONE",
                        "exploitMaturity": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "valueDensity": "NOT_DEFINED",
                        "vulnerabilityResponseEffort": "NOT_DEFINED",
                        "providerUrgency": "NOT_DEFINED",
                        "version": "4.0",
                        "baseSeverity": "HIGH",
                        "baseScore": 7.1,
                        "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N"
                    }
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.  *  EC80ESP+ J1708: Users should update their firmware to version Z300822.\n  *  EC80ESP+ 6S/6M: Users\n\n should update their firmware to version Z300822.\n  *  EC80ESP+ PLC: Users  should update their firmware to version Z300822.\n  *  EC80ESP+ 2nd CAN:\nUsers should update their firmware to version Z300822.\n  *  EC80ESP+ Integrated TPMS: Users should update their firmware to version Z300822.\n  *  EC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\n  *  EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\n  *  EC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\n  *  EC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\n  *  EC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\n  *  EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.<div><ul><li>EC80ESP+ J1708: Users should update their firmware to version Z300822.</li><li>EC80ESP+ 6S/6M:&nbsp;Users\n\n&nbsp;should update their firmware to version Z300822.</li><li>EC80ESP+ PLC:&nbsp;Users&nbsp;&nbsp;should update their firmware to version Z300822.</li><li>EC80ESP+ 2nd CAN:\nUsers&nbsp;should update their firmware to version Z300822.</li><li>EC80ESP+ Integrated TPMS:&nbsp;Users&nbsp;should update their firmware to version Z300822.</li><li>EC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.</li><li>EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.</li><li>EC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.</li><li>EC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.</li><li>EC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.</li><li>EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579.</li></ul></div>"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "Ben Gardiner of NMFTA reported this vulnerability to CISA.",
                    "type": "finder"
                }
            ],
            "source": {
                "advisory": "ICSA-26-237-05",
                "discovery": "EXTERNAL"
            },
            "x_generator": {
                "engine": "Vulnogram 1.0.4"
            }
        }
    }
}