CVE-2026-61884
Tycon Systems TPDIN-Monitor-WEB2 Missing Authentication for Critical Function
02 Description
Tycon Systems TPDIN-Monitor-WEB2 Missing Authentication for Critical Function
03 Exploitation and scoring
- Exploitation
- Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
- SSVC decision
- ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
- AutomatableyesAn attacker can reliably automate reconnaissance through exploitation, so this scales.
- Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
- EPSS probability
- 0.55% probability of exploitation activity in the next 30 days.
- EPSS percentile
- Equal to or higher than the score of 46.1% of scored records. A rank, not a probability.
- NVD base score
- 9.3 (CVSS v4.0), scored by the NVD independently of the CNA.
- NVD CVSS vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- NVD analysis status
- Deferred. NVD last modified this record on 2026-10-24.
- Red Hat severity
- No Red Hat rating. Red Hat rates the CVEs that affect its products.
Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.
04 Metadata
- Published
- 2026-07-24 21:40Z3 MO AGO
- Last updated
- 2026-09-04 21:28Z1 MO AGO
- Reserved
- 2026-07-13
- Assigning CNA
- icscert
- Record state
- PUBLISHED
- Severity
- Critical (CVSS 9.3)
- CNA CVSS vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
- Weaknesses
- CWE-306Missing Authentication for Critical FunctionBase
- Data version
- 5.2
- Document digest
- dbb6fb002ea8705a9747f66483dfa316664a9d91b359957c49366cd0bc041d18
05 Affected products
06 References
07 Remediation
Tycon Systems has released firmware 2.4.5, which resolves this vulnerability by requiring an administrator username and password to be set before the web interface is served. Further inquiries can be directed to security@tyconsystems.com. Tycon Systems recommends setting an administrative username and strong password on the Network Configuration page and confirming in a private browser window that a login is required, for units still running firmware 2.4.4 or earlier. Repeat this after any factory reset. Tycon Systems recommends not exposing the web interface to the Internet, as it is HTTP only. The unit should be kept on a private network, behind a firewall or VPN.