    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-58113",
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "state": "PUBLISHED",
        "assignerShortName": "siemens",
        "dateReserved": "2026-06-29T11:49:12.097Z",
        "datePublished": "2026-09-08T08:11:21.609Z",
        "dateUpdated": "2026-09-08T08:11:21.609Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
                "shortName": "siemens",
                "dateUpdated": "2026-09-08T08:11:21.609Z"
            },
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).\r\nThis could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session."
                }
            ],
            "affected": [
                {
                    "vendor": "Siemens",
                    "product": "Teamcenter V2412",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V2412.0013",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "Teamcenter V2506",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V2506.0010",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "Teamcenter V2512",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V2512.2607",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "Teamcenter V2606",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V2606.2607",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                        "baseScore": 6.1,
                        "baseSeverity": "MEDIUM"
                    }
                },
                {
                    "cvssV4_0": {
                        "version": "4.0",
                        "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N",
                        "baseScore": 8.5,
                        "baseSeverity": "HIGH"
                    }
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-79",
                            "description": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://cert-portal.siemens.com/productcert/html/ssa-157465.html"
                }
            ]
        }
    }
}