    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-4582",
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "state": "PUBLISHED",
        "assignerShortName": "VulDB",
        "dateReserved": "2026-03-22T08:58:54.529Z",
        "datePublished": "2026-03-23T09:33:21.271Z",
        "dateUpdated": "2026-04-18T03:37:10.133Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
                "shortName": "VulDB",
                "dateUpdated": "2026-04-18T03:37:10.133Z"
            },
            "title": "Shenzhen HCC Technology MPOS M6 PLUS Bluetooth missing authentication",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "type": "CWE",
                            "cweId": "CWE-306",
                            "lang": "en",
                            "description": "Missing Authentication"
                        }
                    ]
                },
                {
                    "descriptions": [
                        {
                            "type": "CWE",
                            "cweId": "CWE-287",
                            "lang": "en",
                            "description": "Improper Authentication"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "Shenzhen HCC Technology",
                    "product": "MPOS M6 PLUS",
                    "versions": [
                        {
                            "version": "1V.31-N",
                            "status": "affected"
                        }
                    ],
                    "modules": [
                        "Bluetooth"
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A security vulnerability has been detected in Shenzhen HCC Technology MPOS M6 PLUS 1V.31-N. Affected by this vulnerability is an unknown functionality of the component Bluetooth. Such manipulation leads to missing authentication. The attack must be carried out from within the local network. Attacks of this nature are highly complex. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way."
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "version": "4.0",
                        "baseScore": 2.3,
                        "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                        "baseSeverity": "LOW"
                    }
                },
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "baseScore": 5,
                        "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                        "baseSeverity": "MEDIUM"
                    }
                },
                {
                    "cvssV3_0": {
                        "version": "3.0",
                        "baseScore": 5,
                        "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                        "baseSeverity": "MEDIUM"
                    }
                },
                {
                    "cvssV2_0": {
                        "version": "2.0",
                        "baseScore": 4.3,
                        "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR"
                    }
                }
            ],
            "timeline": [
                {
                    "time": "2026-03-22T00:00:00.000Z",
                    "lang": "en",
                    "value": "Advisory disclosed"
                },
                {
                    "time": "2026-03-22T01:00:00.000Z",
                    "lang": "en",
                    "value": "VulDB entry created"
                },
                {
                    "time": "2026-03-23T12:12:52.000Z",
                    "lang": "en",
                    "value": "VulDB entry last update"
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "davimo (VulDB User)",
                    "type": "reporter"
                },
                {
                    "lang": "en",
                    "value": "VulDB CNA Team",
                    "type": "coordinator"
                }
            ],
            "references": [
                {
                    "url": "https://vuldb.com/vuln/352419",
                    "name": "VDB-352419 | Shenzhen HCC Technology MPOS M6 PLUS Bluetooth missing authentication",
                    "tags": [
                        "vdb-entry"
                    ]
                },
                {
                    "url": "https://vuldb.com/vuln/352419/cti",
                    "name": "VDB-352419 | CTI Indicators (IOB, IOC)",
                    "tags": [
                        "signature",
                        "permissions-required"
                    ]
                },
                {
                    "url": "https://vuldb.com/submit/775433",
                    "name": "Submit #775433 | Shenzhen HCC Technology Co., Ltd M6PLUS MPOS M6PLUS-FW-1V.31-N Missing Cryptographic Authentication",
                    "tags": [
                        "third-party-advisory"
                    ]
                },
                {
                    "url": "https://github.com/Davim09/m6plusexploit/blob/main/docs/CVE-1-Authentication.md",
                    "tags": [
                        "exploit"
                    ]
                }
            ]
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2026-03-23T11:26:35.366868Z",
                                "id": "CVE-2026-4582",
                                "options": [
                                    {
                                        "Exploitation": "poc"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2026-03-23T11:28:45.335Z"
                }
            }
        ]
    }
}