    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-16828",
        "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "state": "PUBLISHED",
        "assignerShortName": "ibm",
        "dateReserved": "2026-07-24T02:25:57.107Z",
        "datePublished": "2026-08-19T18:43:41.541Z",
        "dateUpdated": "2026-08-21T16:14:39.868Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
                "shortName": "ibm",
                "dateUpdated": "2026-08-19T18:59:57.704Z"
            },
            "title": "Power System Out-of-bounds Read",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-125",
                            "description": "CWE-125 Out-of-bounds Read",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "IBM",
                    "product": "Power Systems Firmware",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "FW1120.00"
                        },
                        {
                            "status": "affected",
                            "version": "FW1110.00",
                            "lessThanOrEqual": "FW1110.30",
                            "versionType": "semver"
                        },
                        {
                            "status": "affected",
                            "version": "FW1060.00",
                            "lessThanOrEqual": "FW1060.80",
                            "versionType": "semver"
                        },
                        {
                            "status": "affected",
                            "version": "FW950.00",
                            "lessThanOrEqual": "FW950.H2",
                            "versionType": "semver"
                        }
                    ],
                    "cpes": [
                        "cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
                        "cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
                        "cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
                        "cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
                        "cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
                        "cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
                        "cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "<p>IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.</p>"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://www.ibm.com/support/pages/node/7283898",
                    "tags": [
                        "vendor-advisory",
                        "patch"
                    ]
                }
            ],
            "metrics": [
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV3_1": {
                        "version": "3.1",
                        "attackVector": "ADJACENT_NETWORK",
                        "attackComplexity": "LOW",
                        "privilegesRequired": "NONE",
                        "userInteraction": "NONE",
                        "scope": "UNCHANGED",
                        "confidentialityImpact": "LOW",
                        "integrityImpact": "LOW",
                        "availabilityImpact": "HIGH",
                        "baseSeverity": "HIGH",
                        "baseScore": 7.6,
                        "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H"
                    }
                }
            ],
            "workarounds": [
                {
                    "lang": "en",
                    "value": "Protect access to the FSP's network interface.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "<p>Protect access to the FSP's network interface.</p>"
                        }
                    ]
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "<p>Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.</p><p>Power 11<br/>1) IBM Power System E1180 (9080-HEU)</p><p>Customers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.</p><p>Power 10<br/>1) IBM Power System E1080 (9080-HEX)</p><p>Customers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.</p><p>Power 9<br/>1) IBM Power System S922 (9009-22G)<br/>2) IBM Power System H922 (9223-22S)<br/>3) IBM Power System S914 (9009-41G)<br/>4) IBM Power System S924 (9009-42G)<br/>5) IBM Power System H924 (9223-42S)<br/>6) IBM Power System E950 (9040-MR9)<br/>7) IBM Power System E980 (9080-M9S)</p><p>The images mentioned above can be located at IBM Fix Central : <a href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\">https://www.ibm.com/support/fixcentral/</a></p>"
                        }
                    ]
                }
            ]
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2026-08-21T16:08:23.424581Z",
                                "id": "CVE-2026-16828",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2026-08-21T16:14:39.868Z"
                }
            }
        ]
    }
}