    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-15570",
        "assignerOrgId": "5431be70-064b-4f6a-be51-69eacabef109",
        "state": "PUBLISHED",
        "assignerShortName": "Vestel",
        "dateReserved": "2026-07-13T07:02:12.638Z",
        "datePublished": "2026-08-07T13:32:45.790Z",
        "dateUpdated": "2026-08-07T14:26:15.788Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "5431be70-064b-4f6a-be51-69eacabef109",
                "shortName": "Vestel",
                "dateUpdated": "2026-08-07T13:32:45.790Z"
            },
            "title": "Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command",
            "datePublic": "2026-08-07T13:13:00.000Z",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-918",
                            "description": "CWE-918 Server-Side request forgery (SSRF)",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-664",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-664 Server Side Request Forgery"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "Vestel",
                    "product": "Telefunken TE24553B45V2DZ Smart TV",
                    "platforms": [
                        "Vestel MB181 / Voltron181 / TiVo OS"
                    ],
                    "modules": [
                        "Smart Center",
                        "browserseturl command"
                    ],
                    "versions": [
                        {
                            "status": "affected",
                            "version": "V2.78.0.0"
                        },
                        {
                            "status": "unaffected",
                            "version": "V2.85.2.0"
                        }
                    ],
                    "defaultStatus": "unknown"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0."
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media&token=61fb45d3-b88e-4810-a620-693a1c693db4",
                    "tags": [
                        "vendor-advisory"
                    ]
                },
                {
                    "url": "https://vestelinternational.com/security-advisories",
                    "tags": [
                        "vendor-advisory"
                    ]
                }
            ],
            "metrics": [
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV4_0": {
                        "attackVector": "ADJACENT",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "privilegesRequired": "NONE",
                        "userInteraction": "NONE",
                        "vulnConfidentialityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "vulnIntegrityImpact": "HIGH",
                        "subIntegrityImpact": "NONE",
                        "vulnAvailabilityImpact": "LOW",
                        "subAvailabilityImpact": "NONE",
                        "exploitMaturity": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "valueDensity": "NOT_DEFINED",
                        "vulnerabilityResponseEffort": "NOT_DEFINED",
                        "providerUrgency": "NOT_DEFINED",
                        "version": "4.0",
                        "baseSeverity": "HIGH",
                        "baseScore": 7.1,
                        "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N"
                    }
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "value": "Upgrade the affected product to firmware version V2.85.2.0.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "Upgrade the affected product to firmware version V2.85.2.0."
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "Francesco Caligiuri",
                    "type": "finder"
                }
            ],
            "source": {
                "advisory": "VSA-4",
                "discovery": "UNKNOWN"
            },
            "x_generator": {
                "engine": "Vulnogram 1.0.4"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2026-08-07T14:25:53.841501Z",
                                "id": "CVE-2026-15570",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2026-08-07T14:26:15.788Z"
                }
            }
        ]
    }
}