02 Records
FEED: ACQUIRING
01 RecordSTATE: PUBLISHED
02 Description
CNA: icscertToptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function
03 Exploitation and scoring
SRC: CISA, FIRST, NVD, RED HAT- Exploitation
- Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
- SSVC decision
- ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
- AutomatablenoAt least one step from reconnaissance to exploitation cannot be reliably automated.
- Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
CISA publishes the decision points, not a final SSVC decision. The decision also depends on mission and well-being impact, which is a property of your deployment rather than of the vulnerability.- EPSS probability
- 0.28% probability of exploitation activity in the next 30 days.
- EPSS percentile
- Ranks above 20.2% of scored records. A rank, not a probability.
- NVD base score
- 8.7 (CVSS v4.0), scored by the NVD independently of the CNA.
- NVD CVSS vector
- CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- NVD analysis status
- Received. NVD last modified this record on 2026-07-31.
- Red Hat severity
- No Red Hat rating. Red Hat rates the CVEs that affect its products.
Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.
SCHEMA: 5.2
- Published
- 2026-07-30 21:29Z1 MO AGO
- Last updated
- 2026-07-31 15:39Z1 MO AGO
- Reserved
- 2026-06-17
- Assigning CNA
- icscert
- Record state
- PUBLISHED
- Severity
- High (CVSS 8.7)
- CNA CVSS vector
- CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
- Weaknesses
- CWE-306Missing Authentication for Critical FunctionBase
- Data version
- 5.2
- Document digest
- 72536cb24c077257b5bee0c5dc4a6278186fec536f94917a916b7cb1d945dced
05 Affected products
PAIRS: 2VendorProductVersionsPlatforms
Toptech SystemsRCU II+0 to < 2025-11-24— SRC: CNA
Toptech Systems provides two methods for remediating affected RCU II+
and Multiload II+ units: First, move the device to a closed or segmented
network without untrusted access.
Run one of the RCU II+/Multiload II+ Vulnerability Removal Tools (VRT)
available at
https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip ,
https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz.
* This option does not require breaking Weights and Measures seals and has the least operational impact.
Install the latest firmware from
https://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/ .
* This method requires stopping the bay and breaking the W&M seal.
Be sure to back up the current ML configuration before performing the
firmware update.
For questions, contact Toptech Systems Support at security@toptech.com.
Additional details are available in Toptech System's firmware
vulnerability notice:
https://s3.amazonaws.com/docs.toptech.com/nonpublic/2025%2012%2001%20RCU%20IIPlus%20MultiLoad%20IIPlus%20Vulnerability%20Notice.pdf .