CVE-2026-12562
Toptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function
02 Description
Toptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function
03 Exploitation and scoring
- Exploitation
- Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
- SSVC decision
- ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
- AutomatablenoAt least one step from reconnaissance to exploitation cannot be reliably automated.
- Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
- EPSS probability
- 0.45% probability of exploitation activity in the next 30 days.
- EPSS percentile
- Equal to or higher than the score of 39.4% of scored records. A rank, not a probability.
- NVD base score
- 8.7 (CVSS v4.0), scored by the NVD independently of the CNA.
- NVD CVSS vector
- CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- NVD analysis status
- Deferred. NVD last modified this record on 2026-09-08.
- Red Hat severity
- No Red Hat rating. Red Hat rates the CVEs that affect its products.
Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.
04 Metadata
- Published
- 2026-07-30 21:29Z3 MO AGO
- Last updated
- 2026-07-31 15:39Z3 MO AGO
- Reserved
- 2026-06-17
- Assigning CNA
- icscert
- Record state
- PUBLISHED
- Severity
- High (CVSS 8.7)
- CNA CVSS vector
- CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
- Weaknesses
- CWE-306Missing Authentication for Critical FunctionBase
- Data version
- 5.2
- Document digest
- 72536cb24c077257b5bee0c5dc4a6278186fec536f94917a916b7cb1d945dced
05 Affected products
06 References
- s3.amazonaws.comhttps://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip
- s3.amazonaws.comhttps://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz
- s3.amazonaws.comhttps://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/
- s3.amazonaws.comhttps://s3.amazonaws.com/docs.toptech.com/nonpublic/2025%2012%2001%20RCU%20IIPlus%20MultiLoad%20IIPlus%20Vulnerability%20Notice.pdf
- www.cisa.govhttps://www.cisa.gov/news-events/ics-advisories/icsa-26-211-03
- github.comhttps://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-211-03.json
07 Remediation
Toptech Systems provides two methods for remediating affected RCU II+ and Multiload II+ units: First, move the device to a closed or segmented network without untrusted access. Run one of the RCU II+/Multiload II+ Vulnerability Removal Tools (VRT) available at https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip , https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz. * This option does not require breaking Weights and Measures seals and has the least operational impact. Install the latest firmware from https://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/ . * This method requires stopping the bay and breaking the W&M seal. Be sure to back up the current ML configuration before performing the firmware update. For questions, contact Toptech Systems Support at security@toptech.com. Additional details are available in Toptech System's firmware vulnerability notice: https://s3.amazonaws.com/docs.toptech.com/nonpublic/2025%2012%2001%20RCU%20IIPlus%20MultiLoad%20IIPlus%20Vulnerability%20Notice.pdf .