{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-106079",
        "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "state": "PUBLISHED",
        "assignerShortName": "juniper",
        "dateReserved": "2026-10-06T15:00:41.622Z",
        "datePublished": "2026-10-28T16:37:49.668Z",
        "dateUpdated": "2026-10-28T16:37:49.668Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "Session Smart Router",
                    "vendor": "Juniper Networks",
                    "versions": [
                        {
                            "lessThan": "7.0.5",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "7.1.7",
                            "status": "affected",
                            "version": "7.1.0",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "7.2.3",
                            "status": "affected",
                            "version": "7.2.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "Session Smart Conductor",
                    "vendor": "Juniper Networks",
                    "versions": [
                        {
                            "lessThan": "7.0.5",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "7.1.7",
                            "status": "affected",
                            "version": "7.1.0",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "7.2.3",
                            "status": "affected",
                            "version": "7.2.0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "datePublic": "2026-10-28T16:00:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<div>An Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability&nbsp;in AccessManager in Juniper Networks Session Smart Router and Session Smart Conductor allows an attacker with config-write privileges to achieve arbitrary command execution as root in the YANG configuration.</div>"
                        }
                    ],
                    "value": "An Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in AccessManager in Juniper Networks Session Smart Router and Session Smart Conductor allows an attacker with config-write privileges to achieve arbitrary command execution as root in the YANG configuration."
                }
            ],
            "exploits": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
                        }
                    ],
                    "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 8.8,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "LOW",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-78",
                            "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
                "shortName": "juniper",
                "dateUpdated": "2026-10-28T16:37:49.668Z"
            },
            "references": [
                {
                    "tags": [
                        "vendor-advisory"
                    ],
                    "url": "https://supportportal.juniper.net/JSA112183"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "The following software releases of Session Smart Router and Session Smart Conductor have been updated to resolve these specific issues:<br><ul><li>7.0.5 \n\nand all subsequent releases;</li><li>7.1.7 \n\nand all subsequent releases;</li><li>7.2.3 and all subsequent releases.</li></ul>\n\n<br>"
                        }
                    ],
                    "value": "The following software releases of Session Smart Router and Session Smart Conductor have been updated to resolve these specific issues:\n  *  7.0.5 \n\nand all subsequent releases;\n  *  7.1.7 \n\nand all subsequent releases;\n  *  7.2.3 and all subsequent releases."
                }
            ],
            "source": {
                "advisory": "JSA112183",
                "defect": [
                    "I95-65021"
                ],
                "discovery": "INTERNAL"
            },
            "title": "Session Smart Router and Session Smart Conductor: Improper validation of a field causes privilege escalation when updating the YANG configuration",
            "workarounds": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "There are no known workarounds for this issue."
                        }
                    ],
                    "value": "There are no known workarounds for this issue."
                }
            ],
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        }
    }
}