    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2026-105425",
        "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "state": "PUBLISHED",
        "assignerShortName": "ivanti",
        "dateReserved": "2026-10-05T12:48:38.617Z",
        "datePublished": "2026-11-10T15:43:00.759Z",
        "dateUpdated": "2026-11-10T15:43:00.759Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
                "shortName": "ivanti",
                "dateUpdated": "2026-11-10T15:43:00.759Z"
            },
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-78",
                            "description": "CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection')",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-88",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-88 OS Command Injection"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "Ivanti",
                    "product": "Sentry",
                    "versions": [
                        {
                            "status": "unaffected",
                            "version": "11.0.0",
                            "versionType": "custom"
                        },
                        {
                            "status": "unaffected",
                            "version": "10.8.3",
                            "versionType": "custom"
                        },
                        {
                            "status": "unaffected",
                            "version": "10.7.4",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "affected"
                },
                {
                    "vendor": "Ivanti",
                    "product": "Endpoint Manager Mobile",
                    "versions": [
                        {
                            "status": "unaffected",
                            "version": "12.11.0.0",
                            "versionType": "custom"
                        },
                        {
                            "status": "unaffected",
                            "version": "12.10.0.1",
                            "versionType": "custom"
                        },
                        {
                            "status": "unaffected",
                            "version": "12.9.0.3",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "affected"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "OS command injection in Ivanti Sentry before versions 10.7.4, 10.8.3, and 11.0.0 as well as in Ivanti EPMM before version 12.10.0.1, 12.9.0.3, and 12.8.0.5 allows a remote authenticated attacker with admin privileges to achieve remote code execution.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "OS command injection in Ivanti Sentry before versions 10.7.4, 10.8.3, and 11.0.0&nbsp;as well as in Ivanti EPMM before version 12.10.0.1, 12.9.0.3, and 12.8.0.5 allows a remote authenticated attacker with admin privileges to achieve remote code execution."
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://hub.ivanti.com/s/article/Security-Advisory-Ivanti-Sentry-CVE-2026-105425-CVE-2026-105669-CVE-2026-123179-and-CVE-2026-123181"
                },
                {
                    "url": "https://hub.ivanti.com/s/article/November-2026-Security-Advisory-Ivanti-EPMM-Multiple-CVEs"
                }
            ],
            "metrics": [
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV3_1": {
                        "version": "3.1",
                        "attackVector": "NETWORK",
                        "attackComplexity": "LOW",
                        "privilegesRequired": "HIGH",
                        "userInteraction": "NONE",
                        "scope": "UNCHANGED",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "availabilityImpact": "HIGH",
                        "baseSeverity": "HIGH",
                        "baseScore": 7.2,
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
                    }
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "x_generator": {
                "engine": "Vulnogram 1.0.5"
            }
        }
    }
}