    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2025-71412",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2026-08-04T20:31:35.645Z",
        "datePublished": "2026-08-07T19:01:23.670Z",
        "dateUpdated": "2026-08-10T21:13:19.828Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2026-08-07T19:01:23.670Z"
            },
            "title": "In CPDLC, False Emergency or Status Messages Will be Accepted as Legitimate",
            "datePublic": "2026-08-07T18:00:00.000Z",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-754",
                            "description": "CWE-754",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "ATN-B1",
                    "product": "CPDLC",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "All versions",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unaffected"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "Injection of false emergency or status messages over CPDLC may lead to misallocation of resources, operational confusion, and improper response actions by flight crews, traffic controllers, and ground operations.  This type of attack can be carried out remotely over radio frequency.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "Injection of false emergency or status messages over CPDLC may lead to misallocation of resources, operational confusion, and improper response actions by flight crews, traffic controllers, and ground operations.  This type of attack can be carried out remotely over radio frequency."
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-219-01",
                    "tags": [
                        "third-party-advisory"
                    ]
                }
            ],
            "metrics": [
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV4_0": {
                        "attackVector": "NETWORK",
                        "attackComplexity": "HIGH",
                        "attackRequirements": "NONE",
                        "privilegesRequired": "LOW",
                        "userInteraction": "NONE",
                        "vulnConfidentialityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "vulnIntegrityImpact": "HIGH",
                        "subIntegrityImpact": "HIGH",
                        "vulnAvailabilityImpact": "LOW",
                        "subAvailabilityImpact": "LOW",
                        "exploitMaturity": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "valueDensity": "NOT_DEFINED",
                        "vulnerabilityResponseEffort": "NOT_DEFINED",
                        "providerUrgency": "NOT_DEFINED",
                        "version": "4.0",
                        "baseSeverity": "HIGH",
                        "baseScore": 7.1,
                        "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L"
                    }
                },
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV3_1": {
                        "version": "3.1",
                        "attackVector": "NETWORK",
                        "attackComplexity": "HIGH",
                        "privilegesRequired": "LOW",
                        "userInteraction": "NONE",
                        "scope": "CHANGED",
                        "confidentialityImpact": "NONE",
                        "integrityImpact": "HIGH",
                        "availabilityImpact": "LOW",
                        "baseSeverity": "HIGH",
                        "baseScore": 7.1,
                        "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L"
                    }
                }
            ],
            "workarounds": [
                {
                    "lang": "en",
                    "value": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.<br>"
                        }
                    ]
                },
                {
                    "lang": "en",
                    "value": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.&nbsp;&nbsp;"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "Martin Strohmeier of Armasuisse reported this vulnerability to CISA.",
                    "type": "finder"
                }
            ],
            "source": {
                "advisory": "ICSA-26-219-01",
                "discovery": "EXTERNAL"
            },
            "x_generator": {
                "engine": "Vulnogram 1.0.4"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2026-08-10T18:48:22.727675Z",
                                "id": "CVE-2025-71412",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2026-08-10T21:13:19.828Z"
                }
            }
        ]
    }
}