synced 14 MIN AGO
01 Record

CVE-2025-64778

Mirion Medical EC2 Software NMIS BioDose Use of Hard-coded Credentials

HighPUBLISHEDCNA: icscert
CNA base score8.4 CVSS v4.0CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N

02 Description

Mirion Medical EC2 Software NMIS BioDose Use of Hard-coded Credentials

03 Exploitation and scoring

Exploitation
Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
SSVC decision
  • ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
  • AutomatablenoAt least one step from reconnaissance to exploitation cannot be reliably automated.
  • Technical ImpactpartialSuccessful exploitation gives limited control of the vulnerable component.
CISA publishes the decision points, not a final SSVC decision. The decision also depends on mission and well-being impact, which is a property of your deployment rather than of the vulnerability.
EPSS probability
0.11% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 1.8% of scored records. A rank, not a probability.
NVD base score
8.4 (CVSS v4.0), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD analysis status
Analyzed. NVD last modified this record on 2026-09-25.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2025-12-02 21:09Z11 MO AGO
Last updated
2025-12-02 21:38Z11 MO AGO
Reserved
2025-11-11
Assigning CNA
icscert
Record state
PUBLISHED
Severity
High (CVSS 8.4)
CNA CVSS vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N
Weaknesses
  • CWE-798Use of Hard-coded CredentialsBase
Data version
5.2
Document digest
d3932a35e40ac8713a655151786eeda7f943a4de9b3fb403f10feb0b6cce883e

05 Affected products

VendorProductVersionsPlatforms
Mirion MedicalEC2 Software NMIS BioDose0 to < 23.0—

06 References

07 Remediation

Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support directly.