    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2025-41090",
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "state": "PUBLISHED",
        "assignerShortName": "INCIBE",
        "dateReserved": "2025-04-16T09:09:36.724Z",
        "datePublished": "2025-10-28T09:17:08.128Z",
        "dateUpdated": "2025-10-28T15:35:02.579Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "microCLAUDIA",
                    "vendor": "CCN-CERT",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "3.2.0"
                        }
                    ]
                }
            ],
            "cpeApplicability": [
                {
                    "nodes": [
                        {
                            "cpeMatch": [
                                {
                                    "criteria": "cpe:2.3:a:ccn-cert:microclaudia:3.2.0:*:*:*:*:*:*:*",
                                    "vulnerable": true
                                }
                            ],
                            "negate": false,
                            "operator": "OR"
                        }
                    ],
                    "operator": "OR"
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "value": "Alejandro Vázquez Vázquez"
                }
            ],
            "datePublic": "2025-10-28T07:00:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "microCLAUDIA in v3.2.0 and prior has an improper access control vulnerability.<br><br>This flaw allows an authenticated user to perform unauthorized actions on other organizations' systems by sending direct API requests. To do so, the attacker can use organization identifiers obtained through a compromised endpoint or deduced manually.<br><br>This vulnerability allows access between tenants, enabling an attacker to list and manage remote assets, uninstall agents, and even delete vaccines configurations.<br>"
                        }
                    ],
                    "value": "microCLAUDIA in v3.2.0 and prior has an improper access control vulnerability.\n\nThis flaw allows an authenticated user to perform unauthorized actions on other organizations' systems by sending direct API requests. To do so, the attacker can use organization identifiers obtained through a compromised endpoint or deduced manually.\n\nThis vulnerability allows access between tenants, enabling an attacker to list and manage remote assets, uninstall agents, and even delete vaccines configurations."
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-578",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-578 Disable Security Software"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "PRESENT",
                        "attackVector": "NETWORK",
                        "baseScore": 7.6,
                        "baseSeverity": "HIGH",
                        "privilegesRequired": "LOW",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "subIntegrityImpact": "NONE",
                        "userInteraction": "NONE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "LOW",
                        "vulnConfidentialityImpact": "HIGH",
                        "vulnIntegrityImpact": "HIGH",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-306",
                            "description": "CWE-306 Missing Authentication for Critical Function",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
                "shortName": "INCIBE",
                "dateUpdated": "2025-10-28T15:35:02.579Z"
            },
            "references": [
                {
                    "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/improper-access-control-ccn-cert-microclaudia"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "Update to v3.2.2 or higher."
                        }
                    ],
                    "value": "Update to v3.2.2 or higher."
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "title": "Improper Access Control in CCN-CERT microCLAUDIA",
            "x_generator": {
                "engine": "Vulnogram 0.4.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-10-28T13:20:58.779894Z",
                                "id": "CVE-2025-41090",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-10-28T13:21:31.284Z"
                }
            }
        ]
    }
}