    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2025-37162",
        "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "state": "PUBLISHED",
        "assignerShortName": "hpe",
        "dateReserved": "2025-04-16T01:28:25.375Z",
        "datePublished": "2025-11-18T19:23:20.504Z",
        "dateUpdated": "2025-11-19T14:39:46.998Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "affected",
                    "product": "HPE Aruba Networking 100 Series Cellular Bridge",
                    "vendor": "Hewlett Packard Enterprise (HPE)",
                    "versions": [
                        {
                            "lessThanOrEqual": "10.7.1.1",
                            "status": "affected",
                            "version": "10.7.0.0",
                            "versionType": "semver"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "reporter",
                    "value": "Nicholas Starke"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<p>A vulnerability in the command line interface of affected devices could allow an authenticated remote attacker to conduct a command injection attack. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system.</p>"
                        }
                    ],
                    "value": "A vulnerability in the command line interface of affected devices could allow an authenticated remote attacker to conduct a command injection attack. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system."
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "NONE",
                        "baseScore": 6.5,
                        "baseSeverity": "MEDIUM",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "HIGH",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
                "shortName": "hpe",
                "dateUpdated": "2025-11-18T19:23:20.504Z"
            },
            "references": [
                {
                    "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04970en_us&docLocale=en_US"
                }
            ],
            "source": {
                "advisory": "HPESBNW04970",
                "discovery": "INTERNAL"
            },
            "title": "Authenticated Command Injection Vulnerability Leading to Arbitrary Remote Command Execution",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "problemTypes": [
                    {
                        "descriptions": [
                            {
                                "type": "CWE",
                                "cweId": "CWE-77",
                                "lang": "en",
                                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')"
                            }
                        ]
                    }
                ],
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-11-19T14:39:43.397325Z",
                                "id": "CVE-2025-37162",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-11-19T14:39:46.998Z"
                }
            }
        ]
    }
}