    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2025-3499",
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "state": "PUBLISHED",
        "assignerShortName": "ENISA",
        "dateReserved": "2025-04-10T08:40:15.892Z",
        "datePublished": "2025-07-09T08:57:26.893Z",
        "dateUpdated": "2025-07-09T13:08:05.257Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "platforms": [
                        "Linux"
                    ],
                    "product": "iSAP Smart Collector",
                    "vendor": "Radiflow",
                    "versions": [
                        {
                            "lessThan": "3.02-1",
                            "status": "affected",
                            "version": "1.20",
                            "versionType": "semver"
                        }
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<span style=\"background-color: rgb(255, 255, 255);\">\n\nThe device has two web servers that expose unauthenticated REST APIs on the management network (TCP\nports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary\ncommands that are executed with administrative permissions by the underlying operating system.<br></span>"
                        }
                    ],
                    "value": "The device has two web servers that expose unauthenticated REST APIs on the management network (TCP\nports 8084 and 8086). Exploiting OS command injection through these APIs, an attacker can send arbitrary\ncommands that are executed with administrative permissions by the underlying operating system."
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 10,
                        "baseSeverity": "CRITICAL",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "CHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-78",
                            "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (’OS Command Injection’)",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
                "shortName": "ENISA",
                "dateUpdated": "2025-07-09T08:57:26.893Z"
            },
            "references": [
                {
                    "tags": [
                        "government-resource"
                    ],
                    "url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2025-3499"
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "title": "Unauthenticated execution of arbitrary commands in Radiflow iSAP Smart Collector",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-07-09T13:06:55.487400Z",
                                "id": "CVE-2025-3499",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "yes"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-07-09T13:08:05.257Z"
                }
            }
        ]
    }
}