{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2025-34147",
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "state": "PUBLISHED",
        "assignerShortName": "VulnCheck",
        "dateReserved": "2025-04-15T19:15:22.564Z",
        "datePublished": "2025-08-04T17:34:59.434Z",
        "dateUpdated": "2025-12-01T16:29:40.960Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "modules": [
                        "Captive portal SSID configuration logic"
                    ],
                    "product": "M300 Wi-Fi Repeater",
                    "vendor": "Shenzhen Aitemi E Commerce Co. Ltd.",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "*"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "value": "Valentin Lobstein (Chocapikk)"
                },
                {
                    "lang": "en",
                    "type": "finder",
                    "value": "Dinesh Aswin S. (esistdini)"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02). When configuring the device in Extender mode via its captive portal, the extap2g SSID field is inserted unescaped into a reboot-time shell script. This allows remote attackers within Wi-Fi range to inject arbitrary shell commands that execute as root during device reboot, leading to full system compromise."
                        }
                    ],
                    "value": "An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02). When configuring the device in Extender mode via its captive portal, the extap2g SSID field is inserted unescaped into a reboot-time shell script. This allows remote attackers within Wi-Fi range to inject arbitrary shell commands that execute as root during device reboot, leading to full system compromise."
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-88",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-88 OS Command Injection"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "attackVector": "ADJACENT",
                        "baseScore": 9.4,
                        "baseSeverity": "CRITICAL",
                        "exploitMaturity": "NOT_DEFINED",
                        "privilegesRequired": "NONE",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "HIGH",
                        "subConfidentialityImpact": "HIGH",
                        "subIntegrityImpact": "HIGH",
                        "userInteraction": "NONE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "HIGH",
                        "vulnConfidentialityImpact": "HIGH",
                        "vulnIntegrityImpact": "HIGH",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-78",
                            "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
                "shortName": "VulnCheck",
                "dateUpdated": "2025-12-01T16:29:40.960Z"
            },
            "references": [
                {
                    "tags": [
                        "technical-description",
                        "exploit"
                    ],
                    "url": "https://chocapikk.com/posts/2025/when-a-wifi-name-gives-you-root/"
                },
                {
                    "tags": [
                        "product"
                    ],
                    "url": "https://www.aliexpress.us/item/3256806767641280.html"
                },
                {
                    "tags": [
                        "third-party-advisory"
                    ],
                    "url": "https://www.vulncheck.com/advisories/shenzhen-aitemi-m300-wifi-repeater-os-command-injection-via-ssid"
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "title": "Shenzhen Aitemi M300 Wi-Fi Repeater OS Command Injection via SSID",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-08-05T15:56:31.676086Z",
                                "id": "CVE-2025-34147",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-08-05T15:56:37.006Z"
                }
            }
        ]
    }
}