    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2025-27253",
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "state": "PUBLISHED",
        "assignerShortName": "Nozomi",
        "dateReserved": "2025-02-21T08:32:26.973Z",
        "datePublished": "2025-03-10T09:04:34.413Z",
        "dateUpdated": "2025-10-07T14:16:49.710Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "N60 multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "B30 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "B90 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "C30 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "C60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "C70 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "C95 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "D30 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "D60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "F35 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "F60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "G30 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "G60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "L30 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "L60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "L90 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "M60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "T35 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "T60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "M60 Multilin",
                    "vendor": "GE Vernova",
                    "versions": [
                        {
                            "lessThanOrEqual": "8.60",
                            "status": "affected",
                            "version": "7.0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "A&nbsp;CWE-15 \"External Control of System or Configuration Setting\"&nbsp;in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
                        }
                    ],
                    "value": "A CWE-15 \"External Control of System or Configuration Setting\" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-1",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "ADJACENT_NETWORK",
                        "availabilityImpact": "LOW",
                        "baseScore": 6.1,
                        "baseSeverity": "MEDIUM",
                        "confidentialityImpact": "LOW",
                        "integrityImpact": "NONE",
                        "privilegesRequired": "NONE",
                        "scope": "CHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-15",
                            "description": "CWE-15 External Control of System or Configuration Setting",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
                "shortName": "Nozomi",
                "dateUpdated": "2025-10-07T14:16:49.710Z"
            },
            "references": [
                {
                    "url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
                },
                {
                    "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27253"
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-03-10T15:33:39.489617Z",
                                "id": "CVE-2025-27253",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-03-10T15:33:49.185Z"
                }
            }
        ]
    }
}