{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.2",
    "cveMetadata": {
        "cveId": "CVE-2025-0416",
        "assignerOrgId": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
        "state": "PUBLISHED",
        "assignerShortName": "NCSC-FI",
        "dateReserved": "2025-01-13T12:24:09.743Z",
        "datePublished": "2025-04-01T04:05:14.236Z",
        "dateUpdated": "2026-08-26T13:22:50.993Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
                "shortName": "NCSC-FI",
                "dateUpdated": "2026-08-26T13:22:50.993Z"
            },
            "title": "Valmet DNA Local privilege escalation through insecure DCOM configuration",
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-250",
                            "description": "CWE-250 Execution with unnecessary privileges",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-233",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-233 Privilege Escalation"
                        }
                    ]
                }
            ],
            "affected": [
                {
                    "vendor": "Valmet",
                    "product": "Valmet DNA",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "C2007",
                            "lessThanOrEqual": "C2022",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unaffected"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "Local privilege escalation through insecure DCOM configuration in Valmet DNA versions prior to C2023. The DCOM object Valmet DNA Engineering has permissions that allow it to run commands as a user with the SeImpersonatePrivilege privilege. The SeImpersonatePrivilege privilege is a Windows permission that allows a process to impersonate another user. An attacker can use this vulnerability to escalate their privileges and take complete control of the system.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "Local privilege escalation through insecure DCOM configuration in Valmet DNA versions prior to C2023.&nbsp;The DCOM object Valmet DNA Engineering has permissions that allow it to run commands as a user with the SeImpersonatePrivilege privilege. The SeImpersonatePrivilege privilege is a Windows permission that allows a process to impersonate another user. An attacker can use this vulnerability to escalate their privileges and take complete control of the system."
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://www.valmet.com/about-us/about/research-and-development/vulnerabilityadvisories/cve-2025-0416/"
                }
            ],
            "metrics": [
                {
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ],
                    "cvssV4_0": {
                        "attackVector": "ADJACENT",
                        "attackComplexity": "LOW",
                        "attackRequirements": "PRESENT",
                        "privilegesRequired": "LOW",
                        "userInteraction": "NONE",
                        "vulnConfidentialityImpact": "HIGH",
                        "subConfidentialityImpact": "HIGH",
                        "vulnIntegrityImpact": "HIGH",
                        "subIntegrityImpact": "HIGH",
                        "vulnAvailabilityImpact": "HIGH",
                        "subAvailabilityImpact": "HIGH",
                        "exploitMaturity": "NOT_DEFINED",
                        "Safety": "NEGLIGIBLE",
                        "Automatable": "YES",
                        "Recovery": "USER",
                        "valueDensity": "DIFFUSE",
                        "vulnerabilityResponseEffort": "HIGH",
                        "providerUrgency": "AMBER",
                        "version": "4.0",
                        "baseSeverity": "HIGH",
                        "baseScore": 8.9,
                        "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/S:N/AU:Y/R:U/V:D/RE:H/U:Amber"
                    }
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "value": "The new version is available from Valmet Automation Customer Service.",
                    "supportingMedia": [
                        {
                            "type": "text/html",
                            "base64": false,
                            "value": "The new version is available from Valmet Automation Customer Service."
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "Sixtus Leonhardsberger and Felix Eberstaller of LimesSecurity",
                    "type": "finder"
                }
            ],
            "source": {
                "discovery": "EXTERNAL"
            },
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-04-01T14:03:57.457938Z",
                                "id": "CVE-2025-0416",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-04-01T14:13:36.829Z"
                }
            }
        ]
    }
}