{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2024-43660",
        "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "state": "PUBLISHED",
        "assignerShortName": "DIVD",
        "dateReserved": "2024-08-14T09:27:41.769Z",
        "datePublished": "2025-01-09T07:56:46.841Z",
        "dateUpdated": "2025-03-11T13:07:16.474Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "Iocharger firmware for AC models",
                    "vendor": "Iocharger",
                    "versions": [
                        {
                            "lessThan": "24120701",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "value": "Wilco van Beijnum"
                },
                {
                    "lang": "en",
                    "type": "analyst",
                    "value": "Harm van den Brink (DIVD)"
                },
                {
                    "lang": "en",
                    "type": "analyst",
                    "value": "Frank Breedijk (DIVD)"
                }
            ],
            "datePublic": "2025-01-09T00:00:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "The CGI script &lt;redacted&gt;.sh can be used to download any file on the filesystem.<br><br>This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.<br><br>Likelihood: High, but credentials required.<br><br>Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.<br><br>CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y<br>CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N).  There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).<br>"
                        }
                    ],
                    "value": "The CGI script <redacted>.sh can be used to download any file on the filesystem.\n\nThis issue affects Iocharger firmware for AC model chargers beforeversion 24120701.\n\nLikelihood: High, but credentials required.\n\nImpact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.\n\nCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y\nCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N).  There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y)."
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-1",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "Automatable": "YES",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "attackVector": "NETWORK",
                        "baseScore": 7.1,
                        "baseSeverity": "HIGH",
                        "privilegesRequired": "LOW",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "subIntegrityImpact": "NONE",
                        "userInteraction": "NONE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/AU:Y",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "NONE",
                        "vulnConfidentialityImpact": "HIGH",
                        "vulnIntegrityImpact": "NONE",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-552",
                            "description": "CWE-552 Files or Directories Accessible to External Parties",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
                "shortName": "DIVD",
                "dateUpdated": "2025-03-11T13:07:16.474Z"
            },
            "references": [
                {
                    "tags": [
                        "third-party-advisory"
                    ],
                    "url": "https://csirt.divd.nl/DIVD-2024-00035/"
                },
                {
                    "tags": [
                        "third-party-advisory"
                    ],
                    "url": "https://csirt.divd.nl/CVE-2024-43660/"
                },
                {
                    "tags": [
                        "product"
                    ],
                    "url": "https://iocharger.com"
                }
            ],
            "source": {
                "advisory": "DIVD-2024-00035",
                "discovery": "EXTERNAL"
            },
            "title": "Arbitrary file download using <redacted>.sh",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "cvssV3_1": {
                            "scope": "UNCHANGED",
                            "version": "3.1",
                            "baseScore": 7.5,
                            "attackVector": "NETWORK",
                            "baseSeverity": "HIGH",
                            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                            "integrityImpact": "NONE",
                            "userInteraction": "NONE",
                            "attackComplexity": "LOW",
                            "availabilityImpact": "NONE",
                            "privilegesRequired": "NONE",
                            "confidentialityImpact": "HIGH"
                        }
                    },
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-01-09T14:37:36.870610Z",
                                "id": "CVE-2024-43660",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "yes"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-01-09T14:38:13.440Z"
                }
            }
        ]
    }
}