synced 13 MIN AGO
01 Record

CVE-2024-21917

Rockwell Automation FactoryTalk® Service Platform Service Token Vulnerability

CriticalPUBLISHEDCNA: Rockwell
CNA base score9.8 CVSS v3.xCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

02 Description

Rockwell Automation FactoryTalk® Service Platform Service Token Vulnerability

03 Exploitation and scoring

Exploitation
Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
SSVC decision
  • ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
  • AutomatableyesAn attacker can reliably automate reconnaissance through exploitation, so this scales.
  • Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
CISA publishes the decision points, not a final SSVC decision. The decision also depends on mission and well-being impact, which is a property of your deployment rather than of the vulnerability.
EPSS probability
0.85% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 58.0% of scored records. A rank, not a probability.
NVD base score
9.1 (CVSS v3.x), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
NVD analysis status
Modified. NVD last modified this record on 2026-06-17.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2024-01-31 18:16Z2 YR AGO
Last updated
2026-01-15 15:34Z9 MO AGO
Reserved
2024-01-03
Assigning CNA
Rockwell
Record state
PUBLISHED
Severity
Critical (CVSS 9.8)
CNA CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weaknesses
  • CWE-347Improper Verification of Cryptographic SignatureBase
Data version
5.2
Document digest
24ee8caf0d7baa0b49dd179d80c832e8ef390b2fd32507091d23e0023f5b788f

05 Affected products

VendorProductVersionsPlatforms
Rockwell AutomationFactoryTalk® Service Platform<= v6.31—

06 References

07 Remediation

Customers using Rockwell Automation FactoryTalk® Service Platform are encouraged to apply the risk mitigations, if possible. Additionally, we encourage customers to implement our suggested security best practices to minimize the risk of vulnerability. * Update to v6.40 or later. * Set DCOM authentication level to 6, Mitigating Microsoft DCOM Hardening Patch (CVE-2021-26414) for Affected Rockwell Automation Products (custhelp.com) https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1134040 * When it is not possible to update to v6.40 or later, enable verification of the publisher information (i.e., digital signature) of any executable attempting to use the FactoryTalk® Services APIs. This helps prevent a malicious user from calling the API to receive the service token. This setting can be changed from the Application Authorization node located within System Policies using the FactoryTalk® Administration Console application. * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight