synced 3 MIN AGO
01 Record

CVE-2024-10772

SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modification

HighPUBLISHEDCNA: SICK AG
CNA base score8.8 CVSS v3.xCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

02 Description

SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modification

03 Exploitation and scoring

Exploitation
Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
SSVC decision
  • ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
  • AutomatablenoAt least one step from reconnaissance to exploitation cannot be reliably automated.
  • Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
CISA publishes the decision points, not a final SSVC decision. The decision also depends on mission and well-being impact, which is a property of your deployment rather than of the vulnerability.
EPSS probability
0.34% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 27.6% of scored records. A rank, not a probability.
NVD base score
8.8 (CVSS v3.x), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
NVD analysis status
Deferred. NVD last modified this record on 2026-06-17.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2024-12-06 12:28Z1 YR AGO
Last updated
2024-12-09 14:46Z1 YR AGO
Reserved
2024-11-04
Assigning CNA
SICK AG
Record state
PUBLISHED
Severity
High (CVSS 8.8)
CNA CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weaknesses
  • CWE-649Reliance on Obfuscation or Encryption of Security-Relevant Inputs without Integrity CheckingBase
Data version
5.1
Document digest
5a1b751dd059f466899c332e15d2fc68fe4194477429a5274922df40a16e83d4

05 Affected products

VendorProductVersionsPlatforms
SICK AGSICK InspectorP61x0 to < <5.0.0—
SICK AGSICK InspectorP62x0 to < <5.0.0—
sickinspector61x_firmware0 to < 5.0.0—
sickinspector62x_firmware0 to < 5.0.0—

06 References

07 Remediation

For InspectorP61x and InspectorP62x: Customers are strongly recommended to upgrade to the latest release.