synced 1 MIN AGO
01 Record

CVE-2024-0172

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability,

HighPUBLISHEDCNA: dell
CNA base score7.9 CVSS v3.xCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:L

02 Description

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability,

03 Exploitation and scoring

Exploitation
Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
SSVC decision
  • ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
  • AutomatablenoAt least one step from reconnaissance to exploitation cannot be reliably automated.
  • Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
CISA publishes the decision points, not a final SSVC decision. The decision also depends on mission and well-being impact, which is a property of your deployment rather than of the vulnerability.
EPSS probability
0.14% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 3.4% of scored records. A rank, not a probability.
NVD base score
7.8 (CVSS v3.x), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
NVD analysis status
Analyzed. NVD last modified this record on 2026-06-17.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2024-04-03 09:09Z2 YR AGO
Last updated
2024-08-20 20:30Z2 YR AGO
Reserved
2023-12-14
Assigning CNA
dell
Record state
PUBLISHED
Severity
High (CVSS 7.9)
CNA CVSS vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:L
Weaknesses
  • CWE-269Improper Privilege ManagementClass
Data version
5.1
Document digest
109f4aab4490d6dcb4d7c1adb2aab1b95e13641ae3b7aba370be5c36be3c89b3

05 Affected products

VendorProductVersionsPlatforms
DellPowerEdge Platform< 1.5.6, < 1.1.3, < 1.1.4, < 1.2.5, < 1.3.6, < 1.4.6, < 1.11.2, < 1.7.3, < 1.12.1, < 2.12.4, < 2.19.1, < 2.19.0, < 2.14.1, < 1.20.0—
dellpoweredge_r660_firmware0 to < 1.5.6—
dellpoweredge_r760_firmware0 to < 1.5.6—
dellpoweredge_c6620_firmware0 to < 1.5.6—
dellpoweredge_mx760c_firmware0 to < 1.5.6—
dellpoweredge_r860_firmware0 to < 1.5.6—
dellpoweredge_r960_firmware0 to < 1.5.6—
dellpoweredge_hs5610_firmware0 to < 1.5.6—
dellpoweredge_hs5620_firmware0 to < 1.5.6—
dellpoweredge_r660xs_firmware0 to < 1.5.6—
dellpoweredge_r760xs_firmware0 to < 1.5.6—
dellpoweredge_r760xd2_firmware0 to < 1.5.6—
dellpoweredge_t560_firmware0 to < 1.5.6—
dellpoweredge_r760xa_firmware0 to < 1.1.3—
dellpoweredge_xe9680_firmware0 to < 1.1.3—
dellpoweredge_xr5610_firmware0 to < 1.1.4—
dellpoweredge_xr8620t_firmware0 to < 1.1.3—
dellpoweredge_xr7620_firmware0 to < 1.5.6—
dellpoweredge_xe8640_firmware0 to < 1.2.5—
dellpoweredge_xe9640_firmware0 to < 1.3.6—
dellpoweredge_r6615_firmware0 to < 1.4.6—
dellpoweredge_r7615_firmware0 to < 1.4.6—
dellpoweredge_r6625_firmware0 to < 1.4.6—
dellpoweredge_r7625_firmware0 to < 1.4.6—
dellpoweredge_r650_firmware0 to < 1.11.2—
dellpoweredge_r750_firmware0 to < 1.11.2—
dellpoweredge_r750xa_firmware0 to < 1.11.2—
dellpoweredge_c6520_firmware0 to < 1.11.2—
dellpoweredge_mx750c_firmware0 to < 1.11.2—
dellpoweredge_r550_firmware0 to < 1.11.2—
dellpoweredge_r450_firmware0 to < 1.11.2—
dellpoweredge_r650xs_firmware0 to < 1.11.2—
dellpoweredge_r750xs_firmware0 to < 1.11.2—
dellpoweredge_t550_firmware0 to < 1.11.2—
dellpoweredge_xr11_firmware0 to < 1.11.2—
dellpoweredge_xr12_firmware0 to < 1.11.2—
dellpoweredge_t150_firmware0 to < 1.7.3—
dellpoweredge_t350_firmware0 to < 1.7.3—
dellpoweredge_r250_firmware0 to < 1.7.3—
dellpoweredge_r350_firmware0 to < 1.7.3—
dellpoweredge_xr4510c_firmware0 to < 1.12.1—
dellpoweredge_xr4520c_firmware0 to < 1.12.1—
dellpoweredge_r6515_firmware0 to < 2.12.4—
dellpoweredge_r6525_firmware0 to < 2.12.4—
dellpoweredge_r7515_firmware0 to < 2.12.4—
dellpoweredge_r7525_firmware0 to < 2.12.4—
dellpoweredge_c6525_firmware0 to < 2.12.4—
dellpoweredge_xe8545_firmware0 to < 2.12.4—
dellpoweredge_r740_firmware0 to < 2.19.1—
dellpoweredge_r740xd_firmware0 to < 2.19.1—
dellpoweredge_r640_firmware0 to < 2.19.1—
dellpoweredge_r940_firmware0 to < 2.19.1—
dellpoweredge_r540_firmware0 to < 2.19.1—
dellpoweredge_r440_firmware0 to < 2.19.1—
dellpoweredge_t440_firmware0 to < 2.19.1—
dellpoweredge_xr2_firmware0 to < 2.19.1—
dellpoweredge_r740xd2_firmware0 to < 2.19.1—
dellpoweredge_r840_firmware0 to < 2.19.1—
dellpoweredge_r940xa_firmware0 to < 2.19.1—
dellpoweredge_t640_firmware0 to < 2.19.1—

21 further entries not shown. The complete list is in the raw JSON document.

06 References