    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-6215",
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "state": "PUBLISHED",
        "assignerShortName": "hp",
        "dateReserved": "2023-11-20T16:18:25.230Z",
        "datePublished": "2025-10-07T14:31:53.244Z",
        "dateUpdated": "2025-10-07T15:14:47.089Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "HP Sure Start IFD Protection",
                    "vendor": "HP, Inc.",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "See HP security bulletin reference for affected versions"
                        }
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<span style=\"background-color: rgb(255, 255, 255);\">A potential security vulnerability has been identified in HP Sure Start’s protection of the Intel Flash Descriptor in certain HP PC products, which might allow security bypass, arbitrary code execution, loss of integrity or confidentiality, or denial of service. HP is releasing BIOS updates to mitigate the potential vulnerability.</span>"
                        }
                    ],
                    "value": "A potential security vulnerability has been identified in HP Sure Start’s protection of the Intel Flash Descriptor in certain HP PC products, which might allow security bypass, arbitrary code execution, loss of integrity or confidentiality, or denial of service. HP is releasing BIOS updates to mitigate the potential vulnerability."
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "attackVector": "PHYSICAL",
                        "baseScore": 7.2,
                        "baseSeverity": "HIGH",
                        "privilegesRequired": "NONE",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "HIGH",
                        "subConfidentialityImpact": "HIGH",
                        "subIntegrityImpact": "HIGH",
                        "userInteraction": "NONE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:H/SI:H/SA:H",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "HIGH",
                        "vulnConfidentialityImpact": "LOW",
                        "vulnIntegrityImpact": "HIGH",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
                "shortName": "hp",
                "dateUpdated": "2025-10-07T14:31:53.244Z"
            },
            "references": [
                {
                    "url": "https://support.hp.com/us-en/document/ish_13064666-13064688-16/hpsbhf04061"
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "title": "HP Sure Start IFD Protection - BIOS Security Update",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "problemTypes": [
                    {
                        "descriptions": [
                            {
                                "type": "CWE",
                                "cweId": "CWE-306",
                                "lang": "en",
                                "description": "CWE-306 Missing Authentication for Critical Function"
                            }
                        ]
                    }
                ],
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2025-10-07T15:13:31.595183Z",
                                "id": "CVE-2023-6215",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2025-10-07T15:14:47.089Z"
                }
            }
        ]
    }
}