A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer).

UnratedPUBLISHEDCNA: mitre
CNA base scoreUnratedNo CNA CVSS vector

02 Description

A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer).

03 Exploitation and scoring

Exploitation
Not assessed. CISA has not published an exploitation assessment for this record, and it is not in the KEV catalog. That is an absence of assessment, not a finding of no risk.
SSVC decision
Not assessed by CISA
EPSS probability
0.30% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 23.3% of scored records. A rank, not a probability.
NVD base score
7.8 (CVSS v3.x), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
NVD analysis status
Modified. NVD last modified this record on 2026-08-11.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2021-10-01 02:21Z5 YR AGO
Last updated
2026-08-11 12:22Z2 MO AGO
Reserved
2021-05-28
Assigning CNA
mitre
Record state
PUBLISHED
Severity
Not rated by the issuing CNA
CNA CVSS vector
Not published by the issuing CNA
Weaknesses
  • CWE-829Inclusion of Functionality from Untrusted Control SphereBase
Data version
5.2
Document digest
30efbca4382e2e4e914868d5ff39e1f321d45a4387a2e5981bcb0897e7b62900

05 Affected products

VendorProductVersionsPlatforms
insydeinsydeh2oNot specified—
siemensruggedcom_apr1808Not specified—
siemensruggedcom_apr1808_firmwareNot specified—
siemenssimatic_field_pg_m5Not specified—
siemenssimatic_field_pg_m5_firmwareNot specified—
siemenssimatic_field_pg_m6Not specified—
siemenssimatic_field_pg_m6_firmwareNot specified—
siemenssimatic_ipc127eNot specified—
siemenssimatic_ipc127e_firmwareNot specified—
siemenssimatic_ipc227gNot specified—
siemenssimatic_ipc227g_firmwareNot specified—
siemenssimatic_ipc277gNot specified—
siemenssimatic_ipc277g_firmwareNot specified—
siemenssimatic_ipc327gNot specified—
siemenssimatic_ipc327g_firmwareNot specified—
siemenssimatic_ipc377gNot specified—
siemenssimatic_ipc377g_firmwareNot specified—
siemenssimatic_ipc427eNot specified—
siemenssimatic_ipc427e_firmwareNot specified—
siemenssimatic_ipc477eNot specified—
siemenssimatic_ipc477e_firmwareNot specified—
siemenssimatic_ipc477e_proNot specified—
siemenssimatic_ipc477e_pro_firmwareNot specified—
siemenssimatic_ipc627eNot specified—
siemenssimatic_ipc627e_firmwareNot specified—
siemenssimatic_ipc647eNot specified—
siemenssimatic_ipc647e_firmwareNot specified—
siemenssimatic_ipc677eNot specified—
siemenssimatic_ipc677e_firmwareNot specified—
siemenssimatic_ipc847eNot specified—
siemenssimatic_ipc847e_firmwareNot specified—
siemenssimatic_itp1000Not specified—
siemenssimatic_itp1000_firmwareNot specified—

06 References