synced 2 MIN AGO
01 Record

CVE-2021-20607

Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4

UnratedPUBLISHEDCNA: Mitsubishi
CNA base scoreUnratedNo CNA CVSS vector

02 Description

Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4

03 Exploitation and scoring

Exploitation
Not assessed. CISA has not published an exploitation assessment for this record, and it is not in the KEV catalog. That is an absence of assessment, not a finding of no risk.
SSVC decision
Not assessed by CISA
EPSS probability
0.99% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 61.9% of scored records. A rank, not a probability.
NVD base score
5.5 (CVSS v3.x), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
NVD analysis status
Modified. NVD last modified this record on 2026-06-17.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2021-12-17 16:10Z4 YR AGO
Last updated
2024-08-03 17:45Z2 YR AGO
Reserved
2020-12-17
Assigning CNA
Mitsubishi
Record state
PUBLISHED
Severity
Not rated by the issuing CNA
CNA CVSS vector
Not published by the issuing CNA
Weaknesses
  • CWE-191Integer Underflow (Wrap or Wraparound)Base
Data version
5.1
Document digest
1e6574e9587a411634b97ceef6ce5e354da6d2c8f4ecdd4b3c5650f3e38647ca

05 Affected products

VendorProductVersionsPlatforms
n/aMitsubishi Electric GX Works2; Mitsubishi Electric MELSOFT Navigator; Mitsubishi Electric EZSocketMitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior, Mitsubishi Electric EZSocket versions 5.4 and prior—

06 References