synced 2 MIN AGO
01 Record

CVE-2020-16238

B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus

MediumPUBLISHEDCNA: icscert
CNA base score6.7 CVSS v3.xCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

02 Description

B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus

03 Exploitation and scoring

Exploitation
Assessed, none found. CISA's assessment recorded neither public exploit code nor evidence of exploitation when it was made.
SSVC decision
  • ExploitationnoneCISA recorded no public exploit code and no evidence of exploitation.
  • AutomatablenoAt least one step from reconnaissance to exploitation cannot be reliably automated.
  • Technical ImpacttotalSuccessful exploitation gives total control of the vulnerable component.
CISA publishes the decision points, not a final SSVC decision. The decision also depends on mission and well-being impact, which is a property of your deployment rather than of the vulnerability.
EPSS probability
0.24% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 16.1% of scored records. A rank, not a probability.
NVD base score
6.7 (CVSS v3.x), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
NVD analysis status
Modified. NVD last modified this record on 2026-06-17.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2022-04-14 20:05Z4 YR AGO
Last updated
2025-04-16 17:55Z1 YR AGO
Reserved
2020-07-31
Assigning CNA
icscert
Record state
PUBLISHED
Severity
Medium (CVSS 6.7)
CNA CVSS vector
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weaknesses
  • CWE-269Improper Privilege ManagementClass
Data version
5.1
Document digest
542e5149c6709f3db4151631c5f596e81f9ef907044f5790099f562a208eef0e

05 Affected products

VendorProductVersionsPlatforms
B. Braun Melsungen AGSpaceCom<= U61, <= L81—
B. Braun Melsungen AGBattery pack with Wi-Fi<= U61, <= L81—
B. Braun Melsungen AGData module compactplusA10, A11—

06 References

07 Remediation

B. Braun recommends applying updates: SpaceCom: Version U62 or later (United States), L82 or later (outside the United States) Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States) Data module compactplus: Version A12 or later Please contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html