synced 2 MIN AGO
01 Record

CVE-2018-18630

A vulnerability was found in McKesson Cardiology product 13.x and 14.x. Insecure file permissions in the default installation may allow an attacker with local system access to execute unauthorized

UnratedPUBLISHEDCNA: mitre
CNA base scoreUnratedNo CNA CVSS vector

02 Description

A vulnerability was found in McKesson Cardiology product 13.x and 14.x. Insecure file permissions in the default installation may allow an attacker with local system access to execute unauthorized

03 Exploitation and scoring

Exploitation
Not assessed. CISA has not published an exploitation assessment for this record, and it is not in the KEV catalog. That is an absence of assessment, not a finding of no risk.
SSVC decision
Not assessed by CISA
EPSS probability
0.32% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 25.6% of scored records. A rank, not a probability.
NVD base score
7.8 (CVSS v3.x), scored by the NVD independently of the CNA.
NVD CVSS vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
NVD analysis status
Modified. NVD last modified this record on 2026-06-17.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2019-09-06 16:24Z7 YR AGO
Last updated
2024-08-05 11:15Z2 YR AGO
Reserved
2018-10-23
Assigning CNA
mitre
Record state
PUBLISHED
Severity
Not rated by the issuing CNA
CNA CVSS vector
Not published by the issuing CNA
Weaknesses
  • CWE-732Incorrect Permission Assignment for Critical ResourceClass
Data version
5.1
Document digest
7f32dae9d2db0b1853cc6dfe170a46a56c08a493ca0d746aea8a9ce9d8edb011

05 Affected products

VendorProductVersionsPlatforms
changehealthcarecardiologyNot specified—
changehealthcarecardiology_firmwareNot specified—
mckessoncardiologyNot specified—
mckessoncardiology_firmwareNot specified—
mckessonhorizon_cardiologyNot specified—
mckessonhorizon_cardiology_firmwareNot specified—

06 References