02 Records
FEED: ACQUIRING
01 RecordSTATE: PUBLISHED
02 Description
CNA: icscertGE Multilink Cross-site Scripting
03 Exploitation and scoring
SRC: CISA, FIRST, NVD, RED HAT- Exploitation
- Not assessed. CISA has not published an exploitation assessment for this record, and it is not in the KEV catalog. That is an absence of assessment, not a finding of no risk.
- SSVC decision
- Not assessed by CISA
- EPSS probability
- 1.19% probability of exploitation activity in the next 30 days.
- EPSS percentile
- Ranks above 65.7% of scored records. A rank, not a probability.
- NVD base score
- 5.4 (CVSS v3.x), scored by the NVD independently of the CNA.
- NVD CVSS vector
- CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
- NVD analysis status
- Modified. NVD last modified this record on 2026-06-17.
- Red Hat severity
- No Red Hat rating. Red Hat rates the CVEs that affect its products.
Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.
SCHEMA: 5.2
- Published
- 2017-08-28 15:00Z9 YR AGO
- Last updated
- 2025-11-04 23:33Z10 MO AGO
- Reserved
- 2015-05-12
- Assigning CNA
- icscert
- Record state
- PUBLISHED
- Severity
- Not rated by the issuing CNA
- CNA CVSS vector
- Not published by the issuing CNA
- Weaknesses
- CWE-79Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')Base
- Data version
- 5.2
- Document digest
- 80760f4fd388cd38cf85e0ce8254872a6b10b1c26afd7011351b4a37d255f62e
05 Affected products
PAIRS: 2VendorProductVersionsPlatforms
SRC: CNA
GE recommends users update switch firmware to the
latest published version to resolve these vulnerabilities. The new
firmware will enable new keys to be calculated and exchanged, resolve
the slow data transfer and potential denial of service, and prevent the identified
cross-site scripting vulnerabilities. The latest firmware is Version
5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for
the ML810, ML3000, and ML3100. This firmware is available through the
“Resources/Software” link in the product web sites at
http://www.gedigitalenergy.com . This firmware is also available through
the EnerVista Launchpad device management tool.
GE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.
Please refer to the GE advisory for specific information on how to
install the firmware and change RSA key. The GE advisory is available
at:
https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf