synced 11 MIN AGO
01 Record

CVE-2014-5412

Schneider Electric SCADA Expert ClearSCADA Improper Authentication

UnratedPUBLISHEDCNA: icscert
CNA base scoreUnratedNo CNA CVSS vector

02 Description

Schneider Electric SCADA Expert ClearSCADA Improper Authentication

03 Exploitation and scoring

Exploitation
Not assessed. CISA has not published an exploitation assessment for this record, and it is not in the KEV catalog. That is an absence of assessment, not a finding of no risk.
SSVC decision
Not assessed by CISA
EPSS probability
1.57% probability of exploitation activity in the next 30 days.
EPSS percentile
Equal to or higher than the score of 74.9% of scored records. A rank, not a probability.
NVD base score
The NVD has published no score for this record
NVD CVSS vector
No NVD score to derive
NVD analysis status
Modified. NVD last modified this record on 2026-06-17.
Red Hat severity
No Red Hat rating. Red Hat rates the CVEs that affect its products.

Exploit-prediction scores from FIRST. Independent scoring and analysis status from the NVD. Vendor severity from Red Hat. Exploitation assessment and catalog membership from CISA.

04 Metadata

Published
2014-09-18 10:00Z12 YR AGO
Last updated
2025-11-04 22:56Z11 MO AGO
Reserved
2014-08-22
Assigning CNA
icscert
Record state
PUBLISHED
Severity
Not rated by the issuing CNA
CNA CVSS vector
Not published by the issuing CNA
Weaknesses
Data version
5.2
Document digest
7a1689503225b88b3706441505688b15ec0ceaabe1e8a093a19574b17f6ab658

05 Affected products

VendorProductVersionsPlatforms
Schneider ElectricClearSCADA2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644)—
Schneider ElectricSCADA Expert ClearSCADA2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094), 2013 R2.1 (build 74.5192), 2014 R1 (build 75.5210)—

06 References

07 Remediation

Schneider Electric advises all ClearSCADA users to take steps to secure the interfaces to the ClearSCADA system. The ClearSCADA database security configuration should be reviewed and updated to limit all system access to authorized users only. The access permissions of existing users should be reduced to only those required by their role (e.g., removing any higher level System Administration privileges from Operations or Engineering users), and specific accounts should be created with appropriate permissions for performing System Administration tasks. Existing ClearSCADA customers using WebX can protect their system from cross-site scripting attacks by disabling the “Allow database shutdown via WebX” option within the ClearSCADA Server Configuration utility. Existing ClearSCADA customers should take measures to ensure their system does not grant any system access until users have supplied a valid username and password. Schneider Electric has corrected the default user security permissions; however, upgrading an existing vulnerable installation to a new version will not affect existing configured database security permissions. Therefore, the measures suggested here are strongly recommended for all users. Schneider Electric has corrected these vulnerabilities in the following service packs: * ClearSCADA 2010 R3.2, Released October 2014, and * SCADA Expert ClearSCADA 2014 R1.1, Released October 2014. If asset owners wish to upgrade to a new ClearSCADA Service Pack, please